Sign In | Join Free | My chinacsw.com |
|
Brand Name : Acrel
Model Number : AMC16Z-FAK48
Certification : CE
Place of Origin : China
MOQ : 1 Pieces
Payment Terms : T/T
Supply Ability : 5000pcs/day
Delivery Time : 2-3 days
Packaging Details : cardboard box
Measurement : U, I, P, Q, S, PF, kWh, kvarh
Reference Frequency : 45~65Hz
Accuracy : kWh Class 0.5
communication : RS485 modus rtu
Warranty : 2years
Installtion Type : DIN Rail Mounting Energy Meter
Rated Voltage : 3*220V/380V
With the rapid development of data center, the energy consumption problems about the data center have become increasingly serious, and energy management and the design of power supply and distribution have become hot problems; efficient and reliable power distribution system scheme for data center is an effective method to improve the power utilization efficiency of the data center and reduce the energy consumption of equipment. In order to achieve the energy conservation of data center, firstly it is necessary to accurately monitor each electricity load, but there are many loading circuits in the data center, and the traditional measuring instruments are incapable of satisfying the requirements for cost, volume, installation, construction and the like; hence, it is necessary to apply multi-circuit monitoring device applicable to the centralized monitoring requirements of data center.
AMC16 series multi-circuit monitoring device of Acrel Company is a measuring device designed
specifically for the power supply management of server in the data center. Such device is small and exquisite in design, capable of centralized monitoring on various electric parameters and on-off states of dozens of circuits, including incoming line circuit and outgoing line circuit, and it achieves the highly integration of monitoring circuits in volume.
Technical parameter
Technical parameters | AMC16Z-FAK24 | AMC16Z-FAK48 | |
Measurement parameters | Voltage, current, frequency, active power, reactive power, power factor, active power, reactive power, switching state | ||
2-31 times harmonics | |||
Bus Voltage | Rated | 220VAC | |
Measurement | ±20% | ||
Overload | Instantaneous voltage 2 times/second | ||
Current | Rated | 50mA | |
outgoing line loop | Range | 0.125~60mA | |
Overload | Duration 1.2 times, instantaneous 10 times/second | ||
Input frequency | 45~60Hz | ||
Measurement accuracy | Outgoing line | Voltage/current/active power/active energy level 0.5, reactive power/reactive energy level 1 | |
Auxiliary power supply | Power supply by AMC16Z-ZA | ||
Environment | Temperature | Working:-15℃~55℃ Storage:-25℃~70℃ | |
Humidity | Relative humidity | ||
Altitude | ≤2500m | ||
Communication | RS485/Modbus-RTU | ||
Installation method | DIN35mm Guide rail or bottom plate mounting | ||
IP grade | IP20 | ||
Class of pollution | 2 |
![]() |
Acrel DIN Rail Type Multi Circuit Energy Meter 65Hz Data Center Monitor Images |